Komatsu PC01 – HYDRAULIC EXCAVATOR – Valve clearance

1) Remove the four cylinder head cover bolt, cylinder head cover and gasket.

2) Set the piston at top dead center of the compression stroke (both valves fully closed). The triangular mark on the starter pulley will align with the top hole on the fan cover when the piston is at top dead center of the compression or exhaust stroke.

3) Insert a feeler gauge between the rocker arm and valve to measure valve clearance.

4) If adjustment is necessary, proceed as follows:
a. Hold the rocker arm pivot and loosen the rocker arm pivot lock nut.
b. Turn the rocker arm pivot to obtain the specified clearance.
c. Retighten the rocker arm pivot lock nut while holding the rocker arm pivot.
d. Recheck valve clearance after tightening the rocker arm pivot lock nut.

 