SENR6616-00
4 Page, B/W, D.M.
©
2003 Caterpillar
All Rights Reserved
Printed in U.S.A.
SENR6616
February 1994
930t Series II
Wheel Loader
17B2000-UP
A AA
1
2
325-PK-14
200-BK-14
T
This indicates that the component does not have a wire connected to ground. It is
grounded by being fastened to the machine.
This indicates that the component has a wire connected to it that is connected to ground.
105-9344
T
Normally open switch that will close with an increase of a specific condition (temp-press-etc.).
The circle indicates that the component has screw terminals and a wire can be disconnected from it.
Pin
Socket
Fuse
Component
Part Number
Pin or Socket
Number
Receptacle
Plug
Wire Gauge
Wire, Cable, or Harness
Assembly Identification
Wire Color
Normally closed switch that will open with an increase of a specific condition.
No circle indicates that the wire cannot be disconnected from the component.
Single Wire
Connector
Circuit Number
Identification
Ground
Connection
Pressure
Symbol
Temperature
Symbol
Level
Symbol
Flow
Symbol
Circuit Breaker
Symbol
Reed Switch - A switch whose contacts are controlled by a magnet. A magnet closes the
contacts of a normally open reed switch; it opens the contacts of a normally closed reed switch.
Sender- A component that is used with a temperature or pressure gauge. The sender
measures the temperature or pressure. Its resistance changes to give an indication to
the gauge of the temperature or pressure.
Relay (Magnetic Switch) - A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. The
electromagnet can open or close the switch part of the relay.
Solenoid - A solenoid is an electrical component that is activated by electricity. It has a
coil that makes an electromagnet when current flows through it. The electromagnet
can open or close a valve or move a piece of metal that can do work.
Harness And Wire Symbols
Electrical Schematic Symbols And Definitions
1
1
2
2
Typical representation of a Sure-Seal
connector. The plug and receptacle
contain both pins and sockets.
Typical representation of a Deutsch
connector. The plug contains all
sockets and the receptacle contains
all pins.
SENR6616-00
4 PAGE, B/W, D.M.
G S
MTR BAT
MOTOR
T
S
OR
WH
ST
ON
OFF
B
S
C
R
+ -
NEGPOS
NEGPOS
* A
ALT
+
R
15A
10A
15A
15A
15A
+ -
T-D
H
R
-
+
RD
WH
BK
T
S
RD
WH
BK
BK
BK
1
3
2
1
3
2
AMP
H
REAR LAMP
REAR LAMP
BRAKE IND SW
(NO)
BRAKE IND SW
(NO)
TEST CIRCUIT
PRESS-SW
(NC)
STARTING
MOTOR
ALTERNATOR
STOP/TAIL LAMP
STOP/TAIL LAMP
PARKING
BRAKE IND.
AIR PRESSURE SW
ENGINE OIL
PRESSURE
(NO)
SERVICE METER
BATTERY
12V
BATTERY
12V
DISCONNECT SW
MANUAL
CIRCUIT BREAKER
AMMETER
KEY START SW
LOW AIR
PRESSURE
(NC)
ALARM
DASH LAMP
DASH LAMP
LIGHT SW
AUTO CIRCUIT BREAKER
FUSE
BRAKE LAMP
INDICATOR
STOP LAMP
PRESSURE SW
(NO)
FRONT LAMP
FRONT LAMP
BU
BU
YL
BR
BR
YL
BU
OR
BR
YL
BU
RD
WH
YL/WH
OR
BR
YL
BU
RD
WH
YL/WH
OR
YL
BU
RD
WH
YL/WH
OR
BR
YL
BU
GN
GN
BR
OR
RD
WH
OR
RD OR
OR
OR
OR
GN
OR
OR
BK
GN
GN
GN
WH/BK
OR
OR
OR
PU
OR
BK
BK
RD
RD
RD
BK
WH
YL/WH
YL/WH
YL/WH
ABBREV COLOR
RD RED
WH WHITE
OR ORANGE
YL YELLOW
PK PINK
BK BLACK
GY GRAY
PU PURPLE
BR BROWN
GN GREEN
BU BLUE
COLOR ABBREVIATIONS
SYMBOL DESCRIPTION
BLADE, SPADE, RING OR SCREW
TERMINAL
CIRCUIT CONNECTED
CIRCUIT NOT CONNECTED
ELECTRICAL CONNECTION TO
MACHINE STRUCTURE
INTERNAL ELECTRICAL CONNECTION
TO SURFACE OF COMPONENT
CONNECTOR
ATCH WIRE, CABLE, COMPONENT
CIRCUIT CONNECTED
SPLICE
CIRCUIT GROUPING DESIGNATION
H#
Components are shown installed on a fully operable machine
with the key and engine off.
116-1847
THIS SCHEMATIC IS FOR THE 930T SERIES II.
Note A: NO - Normally Open
NC - Normally Closed
* 40 AMP for 21 AMP Alternator
* 60 AMP for 50 AMP Alternator