Komatsu PC01 – HYDRAULIC EXCAVATOR – Fuel strainer

1) Turn off the fuel valve and remove the strainer cup.

2) Clean the strainer cup with solvent.

3) Install the O-ring and strainer cup.
Tighten the strainer cup to the specified torque.
Torque: 4 N • m (0.4 kg-m, 2.9 ft-lb)